Envelope interchange · 4.92×14.33 in

125×364 mm filter elements

14 elements from 1 brand(s) share this envelope: 125 mm outside diameter and 364 mm overall length (4.92×14.33 in).

Dimensional interchange — verify before substituting. These cartridges fit the same bowl space; they are not guaranteed drop-in equivalents. Compare grade, end caps, seals, collapse rating and bypass configuration for the specific duty.
ModelBrandID (mm)Micronβ ratingCollapse (bar)BypassSealType
RE-250-A-03-B STAUFF 96.1 — — — housing — inline
RE-250-A-03-V STAUFF 96.1 — — — housing — inline
RE-250-A-05-B STAUFF 96.1 — — — housing — inline
RE-250-A-10-B STAUFF 96.1 — — — housing — inline
RE-250-A-10-B-NB STAUFF 96.1 — — — housing — inline
RE-250-A-20-B STAUFF 96.1 — — — housing — inline
RE-250-B-25-B STAUFF 96.1 — — — housing — inline
RE-250-B-50-V STAUFF 96.1 — — — housing — inline
RE-250-D-03-B STAUFF 96.1 — — — housing — inline
RE-250-D-05-B STAUFF 96.1 — — — housing — inline
RE-250-D-10-B STAUFF 96.1 — — — housing — inline
RE-250-D-10-V STAUFF 96.1 — — — housing — inline
RE-250-D-20-B STAUFF 96.1 — — — housing — inline
RE-250-D-20-V STAUFF 96.1 — — — housing — inline

Substitution verification checklist

  1. Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
  2. End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
  3. Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
  4. Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
  5. Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.

Frequently asked questions

Are all 125×364 mm filter elements interchangeable?
They share the same physical envelope — 125 mm OD and 364 mm length (4.92×14.33 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 14 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 125×364 mm in inches?
125×364 mm converts to approximately 4.92×14.33 in.

Browse all 125 mm OD elements or open the dimensions finder.

Request quote & availability

First reply within 2 business hours · first quotation — including the original brand and 1–2 verified equivalents — within 24 hours on business days.