Envelope interchange · 4.49×31.22 in

114×793 mm filter elements

32 elements from 2 brand(s) share this envelope: 114 mm outside diameter and 793 mm overall length (4.49×31.22 in).

Dimensional interchange — verify before substituting. These cartridges fit the same bowl space; they are not guaranteed drop-in equivalents. Compare grade, end caps, seals, collapse rating and bypass configuration for the specific duty.
ModelBrandID (mm)Micronβ ratingCollapse (bar)BypassSealType
1700 R 001 BN4HC /-B6 HYDAC 68 1 ßx(c) ≥ 1000 20 6 bar Nitrile (Buna-N) return
1700 R 001 ON /-KB HYDAC 68 1 ßx(c) ≥ 1000 20 housing Nitrile (Buna-N) return
1700 R 003 ON HYDAC 68 3 ßx(c) ≥ 1000 (HYDAC grade convention: β5(c) ≥ 1000) 20 2.96 bar Nitrile (Buna-N) return
1700 R 003 ON /-B4 HYDAC 68 3 ßx(c) ≥ 1000 (HYDAC grade convention: β5(c) ≥ 1000) 20 4 bar Nitrile (Buna-N) return
1700 R 003 ON /-B6 HYDAC 68 3 ßx(c) ≥ 1000 (HYDAC grade convention: β5(c) ≥ 1000) 20 6 bar Nitrile (Buna-N) return
1700 R 003 ON /-V-KB HYDAC 68 3 ßx(c) ≥ 1000 (HYDAC grade convention: β5(c) ≥ 1000) 20 housing Fluorocarbon (Viton) return
1700 R 005 ON HYDAC 68 5 ßx(c) ≥ 1000 (HYDAC grade convention: β7(c) ≥ 1000) 20 2.96 bar Nitrile (Buna-N) return
1700 R 005 ON /-B6 HYDAC 68 5 ßx(c) ≥ 1000 (HYDAC grade convention: β7(c) ≥ 1000) 20 6 bar Nitrile (Buna-N) return
1700 R 005 ON /-KB HYDAC 68 5 ßx(c) ≥ 1000 (HYDAC grade convention: β7(c) ≥ 1000) 20 housing Nitrile (Buna-N) return
1700 R 005 ON /-SFREE HYDAC 68 5 ßx(c) ≥ 1000 (HYDAC grade convention: β7(c) ≥ 1000) 20 2.96 bar Nitrile (Buna-N) return
1700 R 005 ON /-SFREE-KB HYDAC 68 5 ßx(c) ≥ 1000 (HYDAC grade convention: β7(c) ≥ 1000) 20 housing Nitrile (Buna-N) return
1700 R 005 ON /-V HYDAC 68 5 ßx(c) ≥ 1000 (HYDAC grade convention: β7(c) ≥ 1000) 20 2.96 bar Fluorocarbon (Viton) return
1700 R 010 MM /-KB HYDAC 68 10 β10 > 200 (HYDAC grade convention: β12(c) ≥ 1000) 20 housing Nitrile (Buna-N) return
1700 R 010 ON HYDAC 68 10 ßx(c) ≥ 1000 (HYDAC grade convention: β12(c) ≥ 1000) 20 2.96 bar Nitrile (Buna-N) return
1700 R 010 ON /-B6 HYDAC 68 10 ßx(c) ≥ 1000 (HYDAC grade convention: β12(c) ≥ 1000) 20 6 bar Nitrile (Buna-N) return
1700 R 010 ON /-KB HYDAC 68 10 ßx(c) ≥ 1000 (HYDAC grade convention: β12(c) ≥ 1000) 20 housing Nitrile (Buna-N) return
1700 R 010 ON /-V-KB HYDAC 68 10 ßx(c) ≥ 1000 (HYDAC grade convention: β12(c) ≥ 1000) 20 housing Fluorocarbon (Viton) return
1700 R 010 ON/PO / -KB HYDAC 68 10 ßx(c) ≥ 1000 (HYDAC grade convention: β12(c) ≥ 1000) 20 housing Nitrile (Buna-N) return
1700 R 010 P/HC HYDAC 68 10 β12(c) ≥ 1000 per ISO 16889 10 2.96 bar Nitrile (Buna-N) return
1700 R 020 ON HYDAC 68 20 ßx(c) ≥ 1000 (HYDAC grade convention: β22(c) ≥ 1000) 20 2.96 bar Nitrile (Buna-N) return
1700 R 020 ON /-B6 HYDAC 68 20 ßx(c) ≥ 1000 (HYDAC grade convention: β22(c) ≥ 1000) 20 6 bar Nitrile (Buna-N) return
1700 R 020 ON /-KB HYDAC 68 20 ßx(c) ≥ 1000 (HYDAC grade convention: β22(c) ≥ 1000) 20 housing Nitrile (Buna-N) return
1700 R 020 ON /-SFREE-KB HYDAC 68 20 ßx(c) ≥ 1000 (HYDAC grade convention: β22(c) ≥ 1000) 20 housing Nitrile (Buna-N) return
1700 R 020 ON /-V HYDAC 68 20 ßx(c) ≥ 1000 (HYDAC grade convention: β22(c) ≥ 1000) 20 2.96 bar Fluorocarbon (Viton) return
1700 R 020 ON/PO /-KB HYDAC 68 20 ßx(c) ≥ 1000 (HYDAC grade convention: β22(c) ≥ 1000) 20 housing Nitrile (Buna-N) return
1700 R 040 AM HYDAC 68 40 — 20 2.96 bar Nitrile (Buna-N) return
1700 R 050 W/HC HYDAC 68 50 — 20 2.96 bar Nitrile (Buna-N) return
1700 R 100 W/HC HYDAC 68 100 — 20 2.96 bar Nitrile (Buna-N) return
1700 R 149 W/HC HYDAC 68 149 — 20 2.96 bar Nitrile (Buna-N) return
02.1700R.25G.30.HC.E.P Eaton / Internormen — — — 30 housing Nitrile (Buna-N) inline
02.1700 R.6VG.30.HC.S.P Eaton / Internormen — 7 — 30 housing Nitrile (Buna-N) inline
02.1700R.20VG.30.HC.S.V Eaton / Internormen — — — 30 housing Fluorocarbon (Viton) inline

Substitution verification checklist

  1. Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
  2. End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
  3. Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
  4. Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
  5. Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.

Frequently asked questions

Are all 114×793 mm filter elements interchangeable?
They share the same physical envelope — 114 mm OD and 793 mm length (4.49×31.22 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 32 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 114×793 mm in inches?
114×793 mm converts to approximately 4.49×31.22 in.

Browse all 114 mm OD elements or open the dimensions finder.

Request quote & availability

First reply within 2 business hours · first quotation — including the original brand and 1–2 verified equivalents — within 24 hours on business days.