Envelope interchange · 4.33×6.22 in
110×158 mm filter elements
35 elements from 1 brand(s) share this envelope: 110 mm outside diameter and 158 mm overall length (4.33×6.22 in).
Dimensional interchange — verify before substituting. These cartridges fit the
same bowl space; they are not guaranteed drop-in equivalents. Compare grade,
end caps, seals, collapse rating and bypass configuration for the specific duty.
| Model | Brand | ID (mm) | Micron | β rating | Collapse (bar) | Bypass | Seal | Type |
|---|---|---|---|---|---|---|---|---|
| RVR10020A10B | Filtrec | 55.2 | — | — | — | housing | — | inline |
| RVR10020B10V | Filtrec | 55.2 | 10 | — | — | housing | — | inline |
| RVR10020B25V | Filtrec | 55.2 | 25 | — | — | housing | — | inline |
| RVR10020B60V | Filtrec | 55.2 | 60 | — | — | housing | — | inline |
| RVR10020E03V | Filtrec | 55.2 | 5 | β5(c)≥1000 | — | housing | — | inline |
| RVR10020E05V | Filtrec | 55.2 | 7 | β7(c)≥1000 | — | housing | — | inline |
| RVR10020E10V | Filtrec | 55.2 | 12 | β12(c)≥1000 | — | housing | — | inline |
| RVR10020E20V | Filtrec | 55.2 | 22 | β22(c)≥1000 | — | housing | — | inline |
| RVR10020K10B | Filtrec | 55.2 | 10 | β10(c)≥2 | — | housing | — | inline |
| RVR10020K10V | Filtrec | 55.2 | 10 | β10(c)≥2 | — | housing | — | inline |
| RVR10020K20V | Filtrec | 55.2 | 25 | β25(c)≥2 | — | housing | — | inline |
| XR160C10B0 | Filtrec | 52.5 | 10 | β10(c)≥2 | — | housing | — | inline |
| XR160C10V0 | Filtrec | 52.5 | 10 | β10(c)≥2 | — | housing | — | inline |
| XR160C25B0 | Filtrec | 52.5 | 25 | β25(c)≥2 | — | housing | — | inline |
| XR160C25V0 | Filtrec | 52.5 | 25 | β25(c)≥2 | — | housing | — | inline |
| XR160G03B0 | Filtrec | 52.5 | 5 | β5(c)≥1000 | — | housing | — | inline |
| XR160G03B0/ESD | Filtrec | 52.5 | 5 | β5(c)≥1000 | — | housing | — | inline |
| XR160G03V0 | Filtrec | 52.5 | 5 | β5(c)≥1000 | — | housing | — | inline |
| XR160G06B0 | Filtrec | 52.5 | 7 | β7(c)≥1000 | — | housing | — | inline |
| XR160G06B0/ESD | Filtrec | 52.5 | 7 | β7(c)≥1000 | — | housing | — | inline |
| XR160G06V0 | Filtrec | 52.5 | 7 | β7(c)≥1000 | — | housing | — | inline |
| XR160G10B0 | Filtrec | 52.5 | 12 | β12(c)≥1000 | — | housing | — | inline |
| XR160G10B0/ESD | Filtrec | 52.5 | 12 | β12(c)≥1000 | — | housing | — | inline |
| XR160G10V0 | Filtrec | 52.5 | 12 | β12(c)≥1000 | — | housing | — | inline |
| XR160G25B0 | Filtrec | 52.5 | 22 | β22(c)≥1000 | — | housing | — | inline |
| XR160G25B0/ESD | Filtrec | 52.5 | 22 | β22(c)≥1000 | — | housing | — | inline |
| XR160G25V0 | Filtrec | 52.5 | 22 | β22(c)≥1000 | — | housing | — | inline |
| XR160T100B0 | Filtrec | 52.5 | 100 | — | — | housing | — | inline |
| XR160T100V0 | Filtrec | 52.5 | 100 | — | — | housing | — | inline |
| XR160T25B0 | Filtrec | 52.5 | 25 | — | — | housing | — | inline |
| XR160T25V0 | Filtrec | 52.5 | 25 | — | — | housing | — | inline |
| XR160T40B0 | Filtrec | 52.5 | 40 | — | — | housing | — | inline |
| XR160T40V0 | Filtrec | 52.5 | 40 | — | — | housing | — | inline |
| XR160T60B0 | Filtrec | 52.5 | 60 | — | — | housing | — | inline |
| XR160T60V0 | Filtrec | 52.5 | 60 | — | — | housing | — | inline |
Substitution verification checklist
- Filtration grade. Compare at the same ISO 16889 Beta test point — “10 µm nominal” and “12 µm β1000” may be the same physical media.
- End caps & O-rings. Open/closed cap style and seal position block interchange even with identical OD/length.
- Seal compound. NBR is standard for mineral oil; phosphate-esters, high temperatures or bio-oils can demand fluorocarbon.
- Collapse rating. Low-collapse (~20 bar) return elements must never replace high-collapse (210 bar) pressure elements.
- Bypass strategy. Integral bypass valves (e.g. 3.4 bar) vs reusable housing valves change cold-start behaviour.
Frequently asked questions
Are all 110×158 mm filter elements interchangeable?
They share the same physical envelope — 110 mm OD and 158 mm length (4.33×6.22 in) — so they fit the same bowl. Interchangeability ends there: micron/Beta rating, end-cap geometry, seals, collapse rating and bypass configuration differ across the 35 elements listed and must be checked against the duty.
Is it a drop-in replacement if the OD and length match?
Only after verification. Confirm in order: (1) the filtration grade meets the ISO 4406 cleanliness target at the same Beta test point, (2) end-cap and O-ring arrangement is identical, (3) seal compound suits the fluid (NBR vs fluorocarbon), (4) collapse/burst rating fits pressure-line or cold-start conditions, and (5) the bypass strategy (integral valve vs housing valve) matches.
What is 110×158 mm in inches?
110×158 mm converts to approximately 4.33×6.22 in.
Browse all 110 mm OD elements or open the dimensions finder.
Request quote & availability
First reply within 2 business hours · first quotation — including the original brand and 1–2 verified equivalents — within 24 hours on business days.